Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 45 of 152 items found.

  • PXI/PXIe Battery Simulator Module, 2-Channel, 750 V Isolation

    43-752A-003 - Pickering Interfaces Ltd.

    Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.

  • Food Thermometer

    KM 6503 - Kusam Electrical Industries Limited

    • Temperature Range : -50°C ~ +300°C (-58°F ~ +572°F)• Temperature unit °C / °F changeable.• Data Hold Function• Power Supply : 1.5V x 1 button cell Battery.• Accessories : User Manual, Battery & Plastic tube packing

  • Digital Thermometer

    KT305 - Ketai instrument (kunshan) Ltd.

    Display: 29mm high LCD display.C/F temperature display; clock and date display.Hourly hour and daily alarm function.MAX/MIN temperature and humidity memory function.Storage environment: temperature -20 C~60 C, relative humidity <80% .Battery: One 1.5V AAA battery.

  • Digital Multimeters

    ST-3501 - Standard Electric Works Co., Ltd

    ● Display: 3½ digit liquid crystal display (LCD) with max.    reading of 1999.● Polarity: Automatic, (-) negative polarity indication.● Zero Adjustment: Automatic.● Over Range Indication: Highest digit of (1) or (-1) is displayed.● Low Battery Indication: The (BAT) is displayed when   the battery voltage drops below the operating voltage.● Measurement Rate: 3 measurements per second, nominal.● Operating Temperature: 0°C to ±50°C, 0-70% RH.● Storage Temperature: -20°C to +60°C, 0-80% RH,    with battery removed.● Accuracy: Accuracy specifications at 23±5°C, less than 75% RH.● Power: Single, 006P 9 volt battery● Dimensions: 128(L)×72(W)×33(D)mm.● Weight: Approx .200g

  • Probe Temperature Meter

    Kusam Electrical Industries Limited

    • Measurement Range : -50°C ~ 270°C; -58°F ~ 518°F• Resolution : 0.1°C (-50°C ~ 200°C) ; 1°C (200°C ~ 270°C)• Accuracy : -50°C ~ -20°C : ± (reading x 1.5% + 1°C), -20°C ~ 200°C : ± (reading x 1.0% + 1°C), 200°C ~ 270°C : ± (reading x 2.0% + 4°C)• Auto Power Off : 8min• Low Battery indication• °C / °F display selection

  • Data Logger

    Self-Contained - Hanwell

    The Transport Logger with internal probe is ideal for Chilled Transport temperature monitoring with a range of -10°C to +55°C. This compact unit provides a simple and reusable solutions to temperature data collection in transit with up to 100,000 readings and 2 year battery life. Batteries are easily replaceable, see the datasheet for battery specifications.

  • Thermo-Hygrometer

    MEET International Ltd.

    *Display ambient temperature from -30°C to + 49.8°C*Key chain holder*Water resistant*Keychain (Optional)*Battery powered : 2 x 1.5V (L1154 / LR44 / AG13)

  • Sound Level Calibrator

    TM 100 - Kusam Electrical Industries Limited

    • Standard : Confirms to IEC 942 Class 1.• Output Sound Level : 94dB and 114dB under reference.• Accuracy : ±0.3dB (20°C, 760 mm Hg)• Frequency of 1000 ± 0.1% Hz allows calibration with A / B / C or D weighting networks or linear.• Low Battery Indicator (LED).- Operating Temperature range : -10 ~ +50 C- Storage Temperature range : -40 ~ +65 C (with batteries removed).- Temperature Coefficient : 0 ~ 0.01 dB / C• Calibration of “1 and ½” ceramic microphones.• Altitude Effects : Approx. 0.1 dB decrease for each 2000 feet increase in altitude fromsea level to 12,000 feet elevation, or comparable atmospheric pressure change(approx. every 50 mm of Hg decrease).• Battery : Single 9V transistor Battery. (NEDA 1604)• Battery Life : Approx 100 hours.• Dimension : 48 x 48 x 138mm

  • Test Equipment For IEC 62133

    MTI Corp.

    designed for the battery thermal abuse test for IEC62133-8.2.2. The fire-proof dual-chamber has dimension 10" x 10" x 8", which can be heated up to 180°C via an independent temperature controller with +/- 1°C accuracy.

  • Safety Voltage Detector

    305 SVD - Standard Electric Works Co., Ltd

    ● Bright LED visual indication● Audible indication● AC voltage detection: 100Vac ~ 69kVac ● Frequency range: 40 ~70Hz ● Easy-to-prove method● Self-test function● Power source: 9V alkaline battery ● Non-contact detection by proximity● Convenient to use● Operating temperature and humidity:      0°C~40°C / 80% RH Max.● Lightweight, robust and compact● Easy access to battery● Comply with EN 61326-1

  • 3R Rated UPS Systems – 1kVA to 6kVA with SSG & SSG-RP UPS

    Outdoor NEMA - Falcon Electric, Inc

    *Ready-to-install, Falcon’s SSG and SSG-RP pre-configured NEMA 3R-rated UPS systems provide the ideal solution for outdoor and indoor use. The UPS enclosures are available in various sizes.*-20°C to 55°C (SSG) and -30°C to 65°C (SSG-RP) temperature range. The SSG UPS is agency-certified (UL, cUL, CE) to operate reliably in demanding environments. All 120V UPS models are also UL 508 listed.*High-reliability: true on-line, industrial UPS. Tested and designed with robust components and materials, the SSG assures reliable operation and a long service life in stressful environments. It is a true on-line industrial UPS.*12-year rated batteries cut service costs (SSG UPS). The long-life batteries cut frequent battery replacements and maintenance costs. They have a 12-year life at 25°C and 4 years at 50°C.*Extreme temperature batteries (SSG-RP) The batteries used inside the UPS were specifically selected due to their wide operational range of -40°C to 80°C. They have a 10-year life at 25°C.*Extended battery banks & other options. The battery banks are easily expandable to provide minutes to hours of extra battery runtime. Other options include: environmental protection, remote UPS management, environment sensors, relay cards – and much more.*Falcon – recognized for quality and reliabilityFalcon Electric is a recognized authority in industrial UPS solutions. Our technical expertise assures you find the right solution – the first time

  • Industrial UPS (Wide-temperature)

    SSG Series - Falcon Electric, Inc

    • -20°C to 55°C temperature range. The SSG UPS is agency-certified (UL, cUL, CE) to operate reliably in demanding environments.• Long-life UPS: true on-line, industrial Tested and designed with robust components and materials, the SSGassures reliable operation and a long service life in stressful environments. It is a true on-line industrial UPS.• 12-year rated batteries cut service costs The long-life batteries cut frequent battery replacements and maintenance costs. They have a 12-year life at 25°C and 4 years at 50°C.• Extended battery banks The battery banks are easily expandable to provide minutes to hours of extra battery runtime. • Available options / Advanced communications NEMA 3R-rated enclosures, environmental protection, remote UPS management, environment sensors, relay cards – and much more.• Falcon – recognized for quality and reliability Falcon Electric is a recognized authority in industrial UPS solutions. Our technical expertise assures you find the right solution – the first time

  • SmartWireless Gas Detector

    CXT - Teledyne Gas & Flame Detection

    All component parts are rated for Class 1; Division 1, Group C, D hazardous areas. These advanced field devices consist of a CXT low power gas detection sensor and wireless transceiver packaged in a single enclosure. Power is provided by a disposable “C” cell battery pack capable of continuous operation for greater than 60 days. Additional power options include a Smart Rechargeble battery with a run time of 5-6 months, a disposable “D” cell battery pack with a run time of 9 months and solar panel providing continuous operation. ​

  • RTD Thermometers

    CHY firemate Co., Ltd.

    Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 255g including batteries.

  • Thermocouple Thermometers

    CHY firemate Co., Ltd.

    Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 270g including batteries.

Get Help